ratio.

Find a tool

Browse all tools and categories ↗
ELECTROCHEMISTRY

Nernst Cell Potential Calculator

Calculate a cell potential from standard potential, temperature, electron count and the logarithm of the reaction quotient.

Enter your values

01 / INPUT
Calculated on your device

YOUR CALCULATION

Result

—

Calculation steps

Work through one step at a time or reveal the complete calculation. The steps use your current inputs.

    How to calculate

    Convert the entered common logarithm of Q to a natural logarithm, calculate the Nernst correction and subtract it from standard potential.

    E=E°−RT ln(Q)/(nF); ΔG=−nFE; log10 K=nFE°/(RT ln10)

    Worked example

    At 298.15 K with n=2, E°=1.10 V and Q=100 (log10 Q=2), the correction is about 0.0591593 V and E≈1.0408407 V.

    Assumptions and input details

    Enter a standard cell potential for a specified balanced reaction direction and the positive integer electron count 1–100. Q is dimensionless and must be formed from activities consistent with that reaction; pure solid/liquid standard states are not inserted as concentrations. Input log10 Q avoids overflow across extreme quotients. Constants R and F use rounded/exact-SI-derived values. Kinetics, electrode overpotential, resistance and actual battery performance are not modeled.

    References: OpenStax: potential and the Nernst equation

    Using this calculator

    Can I enter my own problem?

    Yes. Replace the example values with your own inputs. The result, calculation steps, tables and applicable diagrams update from those inputs. Blank or invalid values clear the result; example values are never silently substituted for missing inputs.

    Are the results exact?

    Results use floating-point arithmetic and displayed rounding. Read the formula, assumptions and any stated data precision before interpreting the result.

    Is my input uploaded?

    The calculation runs in your browser. No account, file upload or external AI service is required. Inputs are not saved between page reloads.

    RELATED TOOL · CHEMISTRYFaraday Deposition Mass and Thickness Calculator

    Calculate ideal electrodeposited mass, uniform thickness or elapsed time from entered charge efficiency and material properties.

    RELATED TOOL · CHEMISTRYpH and Ion Concentration Calculator

    Convert pH and ion concentrations or model a single strong or weak monoprotic acid/base. Include water autoionization instead of ignoring dilute-solution effects.

    RELATED TOOL · MATHEMATICSStatistics Calculator

    Enter a list of numbers to calculate mean, median, modes, quartiles, population and sample standard deviation, with a frequency histogram.

    ADVERTISEMENT

    Reserved advertising space.